A leak in a DN3000 (3-meter diameter) fiberglass reinforced plastic pipe (FRP) in a straight section is a major engineering accident, requiring a targeted repair plan based on the cause of the leak, the extent of the damage, and the operating conditions. The following is a system analysis and repair guide.

🔍 1. Leakage Cause Analysis (Combining Structural Characteristics and External Factors)

Production Process Defects

- Uneven Sand Interlayer: Free-fall filling of quartz sand can easily lead to loose pipe walls and stratification. The risk of stratification is higher when the sand content exceeds 30%, making it prone to rupture at weak points under pressure.

- Substandard Impermeable Layer: When the resin lining thickness is less than 0.5mm, it is unable to effectively block media penetration, resulting in "sweating" during pressure testing.

External Mechanical Damage

- Construction Damage: Excavator impacts and direct impacts from rocks during backfill (failure to lay a sand cushion as specified) can cause cracks in the pipe.

- Improper Transportation: Failure to use soft slings during lifting or the lack of wooden cushioning during long-distance transportation can cause hidden cracks. Design and Installation Issues

- Stress Concentration: Water hammer vibrations on large-diameter pipes (DN ≥ 1000) generate thrust at elbows and flanges, leading to joint disconnection or pipe rupture. Elbow repair clamps are used to repair elbow leaks.

- Insufficient Burial Depth: Failure to meet design requirements or lack of steel casing protection across a highway can cause deformation and leakage due to ground loads.

Environmental and Operational Factors

- UV Aging: Long-term exposure to sunlight degrades the surface resin, causing peeling and weakening of the structure.

- Overpressure Operation: Operational errors (such as valves accidentally closing and holding pressure) can exceed the design pressure (usually ≤ 1.0 MPa), resulting in instantaneous impact and cracking.

🔧 II. DN3000 Fiberglass Pipe Leak Repair Plan (Classified by Damage Severity)

For DN3000 Fiberglass Pipe leaks, repairs using half-joint clamps can be performed under water and pressure without shutting off the water.

玻璃钢管承插泄漏维修,哈夫节常州市宝硕管件baoshuo

Injury type       

 Recommended solution               

 Stop time

 Applicable pressure range

Cost Comparison       

 Small hole leakage/cracks    

 Resin paste + fiber reinforcement          

 <8 hours      

 ≤1.0MPa         

 Low (mainly material cost)  

Small hole leakage/cracks

Baoshuo straight pipe repair clamp

0

≤2.5MPa

medium

Large area tear         

Removal and replacement + layered pasting        

 3~7days        

No restrictions           

 High (including labor and materials)

 Flange/socket leakage    

 Sealing ring replacement + external reinforcement      

8~12 hours     

 ≤1.0MPa         

medium               

 Flange/socket leakage

Baoshuo flange half joint, socket repair clamp

0

≤2.5MPa   

medium 

 Unable to stop losing           

 Unable to stop the flow of pressure repair tools, Baoshuo brand straight pipe repair clamp              

0            

≤2.5MPa         

medium   

  Changzhou Baoshuo Pipe Fittings can customize any large-diameter repair clamps, DN3000 straight pipe repair clamps, and DN3000 fiberglass pipe socket connection leak repair clamps.

 